This pressure transducer is an alternate to the GEMS 250 and KPSI transducers. This pressure transducer is mainly used on Xylem / Flowtronex pump stations, but may work in other applications as well. Please contact us for more details. This transducer will work for any applicattion where a 0-250 PSi range with 4-20 milliamp output is called for. Also a direct replacement for Druck transducers on older Flowtronex PSI stations.
NOTE: This transducer can be used as a direct replacement for the GEMS or KPSI transducer.
Pressure transmitter Model S-20for general applications, superiornon-linearity: 0.5% BFSLPressure range: 0...250 psigProcess Connection: 1/4 NPTpermitted media temperature: -30...+100°CSignal output: 4...20 mA, 2-wirePower supply: DC 8...35 VElectrical connection: 1/2 NPT conduit with cable outletCable end: free cable end, with ferrulesPerformance Level: withoutCable length: 6 ftpin assignment el. connection: U+=RD, U-=BK, shield=GYshielding: connectedApprovals: cULusOverpressure safety: 2 timesCalibration Temperature: 15 ... 25 °Cshock and vibration resistance: 100 g shock, 10 g vibrationTest protocol: with test protocolSpecifications: according to WIKA data sheet PE 81.61customer specific: WIKA standard - specification according to data sheetImport documentation CIS-States: without